A portable washroom is a prefabricated sanitation installation that has been assembled off-site, supplied in full to the location of use, and set down without the foundations and service runs that would go with a fixed building.. ZN House groups its range into two lines on its portable washroom solutions page: the EPS portable toilet and the assemble container toilet. The first is built from insulated foam-core panels. The second employs a container-like enclosure with a steel chassis. All the text after that point describing product features was taken from those pages, and is manufacturer-claimed unless otherwise credited to an external reference.

It is clear that the table places the two lines in a comparative perspective, indicating points of weakness on each.
Table 1. EPS portable toilet versus container washroom
|
Factor |
EPS portable toilet |
Container washroom |
|
Construction |
50mm EPS boards mounted to an aluminum profile framework and steel base shelf with weld joints |
Steel reinforcement structure in a box form; galvanized structure and reinforced corners are noted |
|
Handling |
Single cabin listed at 78 kg gross, so it can be moved with light equipment |
Much heavier; expect a forklift or crane for placement and relocation |
|
Site preparation |
Listed as needing no foundation or plumbing connection |
Level site, access to remove waste and tests for water and electricity before delivery |
|
Layout flexibility |
Fixed single and double cabins; handwashing and other modules can be added |
Doors, windows, and walls could be oriented on any transverse axis; stairs may be externally provided; multi-stall blocks |
|
Stated service life |
The pages disagree: 5 to 7 years in one answer, 15 years elsewhere |
Listed as more than 15 years for a well-made unit |
|
Better suited to |
Short deployments, events, parks, shifting work zones |
Multi-year camps, stadiums and other high-traffic sites |
|
Main limits |
Light weight, small capacity per cabin, foam core that needs a fire-test check |
Higher transport and handling effort; more planning before arrival |
Since the figures for service life differ from one page to another, it is wise to put the terms of the warranty in black and white.
The EPS portable toilet page lists a standard configuration for single and double cabins. The page for the container does not provide any measurements or weights, hence no table can be developed for it.
Table 2. EPS portable toilet configurations (manufacturer-listed)
|
Item |
Single cabin |
Double cabin |
|
Size (L × W × H) |
1,100 × 1,100 × 2,300 mm |
2,100 × 1,100 × 2,300 mm |
|
Gross weight |
78 kg |
150 kg |
|
Frame |
Aluminium-alloy profile columns; steel angle base shelf |
Same construction |
|
Roof, ceiling, wall, door |
50 mm EPS panel |
50 mm EPS panel |
|
Floor |
Anti-slip aluminium plate |
Anti-slip aluminium plate |
|
Fittings |
Ventilator fan, squatting pan, basin with faucet, socket, light |
Same fittings |
|
Per 40ft high cube |
20 cabins |
10 cabins |
|
Water use |
Under 5 L per day, with a 0.5 L flush (stated) |
Under 5 L per day, with a 0.5 L flush (stated) |
Two figures require confirmation. The washroom overview page states that 12 EPS units fit in a 40ft high cube, while the EPS page lists 20 single cabins, so a written response is needed for the loading plan. The wind rating is also listed as level 11 in one source and grade 12 in another.
Three reference points answer different questions. They each show you how to ask the right question. There is a construction rule for US workers, a humanitarian level for displaced people in camps, and the manufacturer's formula is a planning tool.
Table 3. Three ways to size toilets for 80 people
|
Reference |
Basis |
Result for 80 people |
|
OSHA 29 CFR 1926.51, Table D-1 (US construction) |
One toilet for 20 or less people; from 20 up to 199, one seat and one urinal for 40; 200 or more, per 50 |
2 toilet seats and 2 urinals |
|
Sphere indicator (displacement camps) |
Toilet to accommodate up to 20 persons; toilet to accommodate 50 persons allowed in the first stage; toilets within 50 m of residences |
4 toilets at 20 per toilet (2 at the first-phase rate of 50 per toilet) |
|
Manufacturer formula for container units |
(Peak workers ÷ 25) × duration factor + buffer, as shown on the product page |
7 container units for an 80-worker, two-year camp (the page’s own example) |
The OSHA figures come from the text of Table D-1 quoted in a US Department of Labor interpretation letter. The Sphere indicator appears in a UNHCR excreta disposal guideline, which also advises that toilets sit no more than 50 m from dwellings. The most common killer is the word "unit". The unit on the EPS page is one cabin. The unit on the container page can contain many fixtures, so 7 container units would be quite different from 7 cabins. Ask all the suppliers to provide toilet information per unit in writing.
This is a planning exercise and not a project history. A 75-member construction workforce is considered to be between 20 to 199 in number; thus, the two toilet and two urinal standard is required. Under the humanitarian guideline of 1:20, the 75-member crew would require. A planner might select four to minimize lines during breaks, adding urinals if most workers are male. This decision also affects servicing needs. The same US guideline further specifies that according to the servicing schedule for the relevant industry, two toilet flushes per week will be sufficient for keeping one toilet used by 20 people clean, while one toilet used by 10 people should be serviced once a week. No number has been mentioned in the letter in regard to four toilets for 40 people.
A dirty toilet isn't available and not counted in the minimum, so capacity is required above and beyond cabins. See the container page for examples of small regular tasks, from emptying waste tanks, cleaning surfaces and testing seals and door hardware, to refillable consumable inventories (insulation and heated piping in cold climates). EPS page states that there is a 200L tank for more than 200 people in foam flush mode with optional heating to 25C please verify this claim against your user count: who will empty the tank? Where does it go?
A short checklist covers most of the risk. It suits crews comparing options for a construction camp, a mining camp or a relief camp.
Do EPS portable toilets need plumbing?
The manufacturer says no foundation, plumbing connection or heavy machinery is required in EPS cabins. They have a tank for waste, so services are still required. Container washrooms will likely require water and electrical services testing before handover.
How many portable toilets does a construction site need?
In the USA, according to the OSHA Table D-1, there should be 1 toilet seat for 20 or less employees, 1 toilet seat and 1 urinal for 20-199 employees, and 1 toilet seat and 1 urinal for each 50 more than 199 employees. The requirements may vary in other countries.
Can portable washrooms work in freezing weather?
They can with the proper options. There is optional heating on the EPS page rated to -25 C and the container page recommends insulation and heated piping for cold weather locations. Verify that you know how the waste tank is kept from freezing at your site.
To size a washroom plan for your crew or event, send your headcount, project length and location through the ZN House portable washroom solutions page to request a quotation.

Disclaimer
This is general information only. Product specifications are derived from current website pages of ZN House and are liable to change at any time. Please refer to product specifications in your quotation. This is not legal, engineering, or public health advice. The number of toilets, toilet servicing, and waste management are liable to vary depending on the location.